Skip to main content
x

Tango® TX2 Two-Gas Monitor

Protect workers, reduce false alarms, and spend less time managing your gas detector fleet with the Tango TX2. Unlike other two-gas monitors that use combination sensors, the Tango TX2 uses individual sensors to increase alarm accuracy so you can reduce unnecessary shutdowns and improve incident data quality.

 Tango® TX2 Two-Gas Monitor

Features

Reduce unexpected project shutdowns from false alarms by increasing alarm accuracy with two individual sensors
Replaceable battery that eliminates the need for charging
Customizable display options to see the gas readings you need most.
Increase compliance and willingness to use the lightweight and hassle-free design

Specification

DISPLAY: Segment liquid crystal display (LCD)
KEYPAD: Two buttons
CASE MATERIALS: Case top: Polycarbonate with a protective rubber overmold. Case bottom: Conductive polycarbonate
ALARMS: Three strobe-emitting visual alarm LEDs (two red; one blue)
100 decibel (dB) audible alarm at a distance of 10 cm (3.94 in); Vibration alarm
DIMENSIONS: 99 x 51 x 35 mm (3.9 x 2.0 x 1.4 in)
WEIGHT: 126.0 g (4.4 oz)
TEMPERATURE RANGE: -40 °C to 50 °C (-40 °F to 122 °F) **
HUMIDITY RANGE: 15-95% non-condensing (continuous)
SENSORS: CO, CO/H2, H2S, NO2, SO2 electrochemical sensor technology
BATTERY: 3.6 V primary lithium-thionyl chloride (Li-SOCl2); 1.5AH, 2/3AA; replaceable; non rechargeable; always on; up to two-year run time depending on operating conditions
DATA LOGGING: 3 months at 10-second intervals
EVENT LOGGING: 60 alarm events
Certifications
DIRECTIVE OR CB AREA CLASSIFICATION STANDARDS
ATEX1: Ex ia I Ma;
Ex ia IIC T4 Ga; Equipment Group and Category: I M1 and II 1G,
EN 60079-0: 2012
EN 60079-11: 2012
EN 50303: 2000
IECEx3 Ex ia I Ma, Ex ia IIC T4 Ga
IEC 60079-0: 2011
IEC 60079-11: 2011
UL (C-US)4: Class I, Groups A, B, C, and D; Class II, Groups E, F, and G; T4;
Exia Class I, Zone 0, AEx ia IIC T4
UL 913 8th Ed.
UL 60079-0 6th Ed.
UL 60079-11 6th Ed.
CSA C22.2 No. 157